Performance Indicators At Room Temperature (+18°C~+28°C)
Performance level Parameters |
Unit |
Level A |
Level B |
Level C |
Operation wavelength |
nm |
1310/1550 |
||
Splitting ratio |
/ |
50.0±3.0% |
50.0±5.0% |
50.0±10.0% |
Additional loss |
dB |
≤0.50 |
≤0.60 |
≤0.80 |
Extinction ratio |
dB |
≥20.0 |
≥18.0 |
≥15.0 |
Return loss |
dB |
>50.0 |
||
Operation temperature |
°C |
~40~+70 |
||
Storage temperature |
°C |
-55~+85 |
||
Pigtail length |
m |
1.0±0.2 (or as required) |
||
Package size |
mm |
Φ3.0x38/Φ2.4x38 |
||
Pigtail specification |
/ |
125/250μm (panda polarization-maintaining fiber or according to user requirements) |
Performance Indicators At Operation Temperature (- 40°C~+70°C)
Performance level Parameters |
Unit |
Level A |
Level B |
Level C |
Variation in additional loss |
dB |
≤0.20 |
≤0.30 |
≤050 |
Variation in splitting ratio |
/ |
≤5.0% |
≤6.0% |
≤7.0% |
Extinction ratio |
dB |
≥18.0 |
≥15.0 |
≥13.0 |
Hotline
Contact
Us